Isotherm, Inc.                                                 ( Enhanced Heat Transfer )
Keyword :
 
 
 
 
Home
Contact us
E-mail
Home Contact Us Send us E-mail
  Home > Marine Products > Shell and Tube Condensers
 
Shell and Tube Condensers
Model Nom. Cap
(TR)
Flow
(gpm)
Dp
(psi)
Water Conn.
(Ins.)
Overall Length
(Ins.
)
Empty Wt.
(Lbs.)
ZC-604D 20 240
2.5
3  68 250
ZC-608D 25 300
4.9
3 116 400
ZC-806D 30 360
1.7
3  92 420
ZC-808D 40 480
3.6
3 116 500
ZC-810D 55 660
7.8
4 144 580
ZC-1008D 75 900
3.8
4 120 750
ZC-1010D 100 1200
7.8
5 144 850
ZC-1208D 115 1380
3.5
5 120 950
ZC-1210D 135 1485
4.4
5 144 1100
ZC-1212D 150 1500
5.9
5 168 1250
ZC-1410D 175 1750
4.3
5 144 1300
ZC-1412D 200 1800
5.4
5 168 1450
ZC-1610D 225 1350
11.7
6 137 1650
ZC-1612D 250 1350
13.6
6 161 1830
ZC-1810D 300 1600
9.2
6 138 1850
ZC-1812D 350 1750
12.6
6 162 2100
ZC-2010D 375 2100
10.3
8 140 2200
ZC-2012D 425 2200
13.2
8 164 2500
ZC-2408D 450 3000
7.8
8 120 2550
ZC-2410D 500 3200
10.8
8 144 3000
ZC-2412D 600 3400
13.9
8 168 3450
Sea water Inlet = 82°F, Ammonia condensing temp = 96°F.
For R22, Capacity Adjustment Multiplier = 0.45@ Condensing temp = 105°F.

 
 
©Copyright 2003 Isotherm, inc reserved.
7401 Commercial Blvd.East
Arlington, Texas 76001
Voice: 817-472-9922 Fax: 817-472-5878
e-mail: info@iso-therm.com
 
Developed By:
Naxtor Technologies
Naxtor Technologies